9.

Fill a clean empty concentrate container with 2 quarts (1.9 liters) of sanitizing solution, place
on dispensing platform, and insert bottle fitting into bottle adapter.

NOTE: Do not reuse the same sanitizing solution used to clean nozzles, static mix-
ers, etc.

10. Place handle in dispense position and close door.

11. Run dispensing station for 90 seconds then stop; allow sanitizing solution to remain in lines

for 5 minutes.

12. Dispense remaining sanitizing solution (approximately 90 seconds).

13. Replace sanitizing solution container with a concentrate container, and close door.

14. Depress and hold push buttons until juice appears at outlet of dispensing nozzle.

15. Dispense and discard two 8 oz. cups (236.6 ML) of juice.

NOTE: Wipe internal and external surfaces of cabinet with a clean damp cloth.

W

EEKLY

: C

HECK

B

RIX

S

ETTING

Tools: Hydrometer or Refractometer

1.

Dispense required ounces of juice per brix testing device instructions.

2.

Test concentrate to water ratio of dispensed juice per brix testing device instructions.

3.

Clockwise rotation of knob decreases brix level (i.e. from 13% to 11.5%). Counterclockwise
rotation of knob increases brix level (i.e. from 11.5% to 13%).

NOTE: If brix problem persists, refer to trouble shooting guide.

S

EMI

-A

NNUAL

: G

ENERAL

C

LEANING

1.

Remove access port of Y-shaped water solenoid located on water inlet in lower cabinet, clean
stainless steel strainer and reinstall.

2.

Clean condenser fins.

3.

Clean air inlet grille located in base of unit.

4.

Clean lower cabinet interior.

5.

Wipe fan blade clean.

Y

EARLY

: R

EPLACE

P

UMP

T

UBING

Removal of Platform (see figure 1):

1.

Remove concentrate container from the dispenser and place in a refrigerator.

2.

Remove the product shelf.

3.

Depress the button on the water line quick disconnect and lift the water line away from the
platform.

4.

Unplug the platform electrical connector at the inside rear of the cabinet.

5.

Release the catch at the front of the platform by pulling the tab towards yourself with on finger.

Advertising