Symptom / Error

FRU / Action in Sequence

188
(EEPROM CRC #2 error.)

1. Set the system

identification using
the ThinkPad 750Ce
hardware
maintenance diskette.

190
(Depleted battery pack was
installed when the power
was on.)

1. Go to “Checking the

Battery Pack” on
page 102.

191XX
(PM initialization error.)

1. System Board
2. CPU card

195
(The configuration read from
the hibernation area does
not match the actual
configuration.)

1. Check if the

configuration was
changed.
For example, check if
the hard disk drive is
from another computer.
Also, when a DIMM
card has been
installed, unsecured
DIMM latches can
result in this error.
Make sure the DIMM is
securely seated and
fully latched into place.

196
(Read error occurred in the
hibernation area of the
HDD.)

1. Run the hard disk

drive test.

2. Hard Disk Drive

199XX
(Resume error.)

1. System Board

1XX

1. System Board

2XX

201

Memory data error.

202

Memory line error
00–15.

203

Memory line error
16–23.

205

Memory test failure
on on-board memory.

221

ROM to RAM remap
error.

1. Go to “Memory

Checkout” on
page 97.

2. DIMM
3. System Board

301, 303, 304, 305, 3XX
(301: Keyboard error.)

1. Go to

“Keyboard/Auxiliary
Input Device
Checkout” on
page 98.

2. Keyboard
3. External Numeric

Keypad

4. External Keyboard
5. Keyboard/Mouse Cable
6. Keyboard Card
7. System Board

108

IBM Mobile Systems - ThinkPad HMM Volume 3