IBM THINKPAD 760C/CD (9546) User Manual

Page 121

Advertising
background image


Symptom / Error

FRU / Action in Sequence

601, 6XX
(601: Diskette drive or
controller error.)

1. Go to “Diskette Drive

Test” on page 99.

2. Diskette Drive

Assembly

3. Diskette
4. System Board

602
(Diskette read error.)

1. Go to “Diskette Drive

Test” on page 99.

2. Diskette
3. Diskette Drive

Assembly

604
(Unacceptable ID was read
from the diskette drive.)

1. Go to “Diskette Drive

Test” on page 99.

2. Diskette Drive

Assembly

3. System Board

11XX
1101: Serial_A test failure.

1. Serial Device
2. Communication Cable
3. System Board

12XX
1201: Serial_B test failure.

1. System Board

17XX

1701

Hard disk controller
failure.

1780, 1790 Hard disk 0

error.

1781, 1791 Hard disk 1

error.

1. Hard Disk Drive

2. System Board

24XX
(2401: System board video
error.)

1. System Board

808X

8081

PCMCIA presence
test failure.
(PCMCIA revision
number also
checked.)

8082

PCMCIA register
test failure.

1. Reseat the PCMCIA

Connector.

2. PCMCIA Slot

Assembly

3. PCMCIA Device
4. System Board

860X
(Pointing device error when
TrackPoint III is disabled.)

8601

System bus
error–8042 mouse
interface.

8602

External mouse
error.

8603

System bus error or
mouse error.

1. External Mouse
2. External Keyboard
3. System Board

ThinkPad 365X, 365XD (2625)

109

Advertising