IBM THINKPAD 760C/CD (9546) User Manual

Page 294

Advertising
background image

Symptom / Error

FRU / Action in Sequence

17XX

1701: Hard disk
controller failure.

1780, 1790: Hard disk
0 error.

1781, 1791: Hard disk
1 error.

1. Hard Disk Drive

2. System Board

24XX
(2401: System board video
error.)

1. System Board

808X

8081: PCMCIA
presence test failure.
(PCMCIA revision
number also checked.)

8082: PCMCIA register
test failure.

1. PCMCIA Slot

Assembly

2. PCMCIA Device
3. System Board

860X
(Pointing device error when
TrackPoint III is disabled.)

8601: System bus
error–8042 mouse
interface.

8602: External mouse
error.

8603: System bus
error or mouse error.

1. External Mouse
2. External Keyboard
3. System Board

861X
(Pointing device error when
TrackPoint III is enabled.)

8611: System bus
error–I/F between 8042
and IPDC.

8612: TrackPoint error.
8613: System board or
TrackPoint error.

1. Reseat the keyboard

cable on the system
board.

2. Keyboard
3. External Mouse
4. System Board

I9990301
I9990302
I9990305

I9990301: Hard disk
error.

I9990302: Invalid hard
disk boot record.

I9990305: No bootable
device.

1. Check that the

operating system is
installed in the HDD.
If not, install the
operating system.

2. Reseat the boot

device.

3. Check the startup

sequence for the
correct boot device.

4. Check that the

operating system has
no failure and is
installed correctly.

I9990303
(Bank–2 flash ROM check
sum error.)

1. System Board

282

IBM Mobile Systems - ThinkPad HMM Volume 3

Advertising