Symptom / Error

FRU / Action in Sequence

185
(The startup sequence is
not valid. Suspect that
power was off when the
startup sequence was being
updated.)

1. Reset the startup

sequence in
Easy-Setup.

186

1. System board

188
(EEPROM CRC #2 error.)

1. Set the system

identification using
the ThinkPad
Hardware
Maintenance Diskette
Version 1.20.

190
(Depleted battery pack was
installed when the power
was on.)

1. Go to “Checking the

Battery Pack” on
page 351.

191XX
(PM initialization error.)

1. System board
2. CPU card

195
(The configuration read from
the hibernation area does
not match the actual
configuration.)

1. Check if the

configuration was
changed.
For example, check if
the disk drive is from
another computer.

196
(Read error occurred in the
hibernation area of the
HDD.)

1. Run the hard disk

drive test.

2. Hard disk drive

1XX

1. System board

2XX

201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.

205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.

1. Go to “Memory

Checkout” on
page 342.

2. DIMM, or DIMM

Adapter

3. System board

301, 303, 304, 305, 3XX
(301: Keyboard error.)

1. Go to “Keyboard and

Auxiliary Input
Device Checkout” on
page 345.

2. Keyboard
3. Video card
4. External numeric

keypad

5. External keyboard
6. Keyboard/mouse cable
7. System board

ThinkPad 760 (9546, 9547)

361