FRU Codes:

If an error is detected by the diagnostic

tests, a

four-digit FRU code is displayed. The FRU code

indicates two suspected FRUs. Replace the FRU that is
indicated by the

two leftmost digits first, then replace the

FRU indicated by the

two rightmost digits. No FRU is

assigned to code 00. If only one FRU is suspected, the
other FRU code is filled with zeros. See the referenced
page before replacing the FRU.

If the problem remains after replacement of the FRUs, go
to “Undetermined Problems” on page 116.

FRU Code

FRU/Action

10

System Board

11

CPU Card

20

Memory
(See “Memory Checkout” on page 97.)

30

Reserved

32

External Keyboard

33

External Mouse

40

LCD Assembly

45

External CRT

50

1. Reseat the Diskette Drive (FDD-1)
2. Diskette Drive (FDD-1)

51

1. Reseat the Diskette Drive (FDD-2)
2. Diskette Drive (FDD-2)

60

1. Reseat the Hard Disk Drive (HDD)
2. Hard Disk Drive (HDD)

72

PCMCIA Slot Assembly

90

CD-ROM Drive

Checking the Installed Devices List

If a device is installed but the icon appears in a gray shade
rather than a dark shade on the basic diagnostics screen,
the device is defective. Reseat the device connectors. If
the symptom remains, replace the device or the system
board. If needed, adjust the contrast control to clearly
distinguish the shade of the icon.

If a device that is not installed appears in a dark shade (for
example, FDD-2 appears in a dark shade when

no second

FDD is installed), do the following:

1. Replace the first device in the configuration, such as

the FDD-1.

2. If the problem remains, replace the system board.

The PCMCIA, Parallel, and Serial icons are always
displayed in a dark shade because the icons represent
subsystems of the system board and not the actual
attachment of the devices.

ThinkPad 365X, 365XD (2625)

123