Symptom-to-FRU Index

The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.

Note: Perform the FRU replacement or actions in the

sequence shown in the “FRU/Action in Sequence”
column. If a FRU did not solve the problem, put
the original part back in the computer. Do not
replace a nondefective FRU.

This index can also be used to help you decide which
FRUs to have available when servicing a computer.

Numeric error codes show the errors detected in POST or
system operation. In the following error codes, X can be
any number.

If no codes are available, use narrative symptoms.

If the symptom is not listed, go to “Undetermined
Problems” on page 371.

Note: For IBM devices not supported by diagnostic

codes in the ThinkPad notebook computers,
see the manual for that device.

Numeric Error Codes

Symptom / Error

FRU / Action in Sequence

10X

101: Interrupt failure.

102: Timer failure.

103: Timer interrupt
failure.

104: Protected mode
failure.

105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.

109: Low meg-chip
select test.

1. System board

110
(System board parity.)

1. Go to “Memory

Checkout” on
page 342.

2. DIMM Adapter Card

and DIMM

3. The computer is

attached to the
expansion unit.

4. System board

ThinkPad 760 (9546, 9547)

359