Error messages – IBM THINKPAD 760C/CD (9546) User Manual

Page 56

Advertising
background image

Error Messages

Error Message/Symptom

FRU/Action

Bus Timeout NMI,
Slot

n

. Type (S)hut off NMI,

(R)eboot, other keys to
continue.

1. System Board

Configuration for slot

n

.

1. Run Setup Utility.

Diskette drive failure

1. See “Diskette Drive

Checkout” on
page 34
.

Diskette drive

x

failure

where

x

=0 or

x

=1.

1. See “Diskette Drive

Checkout” on
page 34
.

Diskette read failure -
press F1 to retry boot (or
may also say F2 for Setup
Utility
).

1. Replace diskette with

a bootable diskette
and retry
.

Gate A20 failure

1. System Board

Hard disk configuration
error

1. Correct the hard disk

configuration.

Hard disk controller
failure

1. System Board

Hard Disk failure

1. Hard Disk

Hard disk failure - press
F1 to retry boot (or may
also say press F2 for
Setup Utility
).

1. Check drive selection

in setup.

2. Hard Disk.

F2 to enter ROM-based
SETUP

1. Run Setup Utility.

2. Verify Configuration.

ID information mismatch
for slot

n

1. Run Setup Utility.

Invalid configuration
information
.

1. Run Setup Utility.

Internal cache test failed -
cache is disabled
.

1. Processor Card
2. System Board

Keyboard clock line
failure
.

1. Keyboard cable and

Keyboard
connection
.

2. System Board

Keyboard controller
failure
.

1. System Board

Keyboard data line failure.

1. System Board

Keyboard is locked.

1. Unlock the Keyboard

Keyboard stuck key
failure
.

1. Locate and fix.
2. Keyboard cable and

Keyboard connection.

3. System Board

Memory failure at

hex-value,

read

hex-value

,

expecting

hex-value

.

1. RAM Memory Board

44

IBM Mobile Systems - ThinkPad HMM Volume 3

Advertising