JAI CB-141MCL User Manual

Page 18

Advertising
background image

CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA

15



















Fig.14. variable partial scan


How to calculate total line number and frame rate in variable partial scan mode

Variable partial scan The start line setting

1st line to 1024nd line

Read out height

8 lines to 1032 lines

Total lines = OB period in the upper part of the frame (L) + Fast Dump period in the upper

part of the frame (L) + Effective image period (L) + Fast dump period in the
lower part of frame(L)

Where, OB period in the upper part of the frame 3L

Fast dump period for the upper part

5

7

.

o

StartlineN

Roundup

+2

Fast dump period for the lower part

5

.

1039 EndLineNo

Roundup

+2

Frame rate (fps) = 1000000 / (Horizontal pixel No x Pixel clock x Total lines)

Horizontal Pixel number 1830

Pixel clock 17.24138 ns

Calculation example

Read out: 1/2 partial at the center (520L), Stat line (261), End line (780)

OB period in the upper part of the frame 3L
Fast dump period for the upper part = (261+7) ÷ 5 +2 = 55.6 → 56
Fast dump period for the lower part = (1039-780) ÷ 5 +2 =53.8 → 54
Total lines = 3+56+520+54=633
Frame rate = 1000000 ч (1830 Ч17.24138 Ч 633) = 50.06 fps

Image Height

Image start
line/end line

Minimum: 8 lines

Maximum: 1032 lines

Image start at 1st line

Image start line from 1 to 1024
Image end line from 8 to 1032

1/8

1024/

8 lines

1032 lines

1032

Advertising
This manual is related to the following products: