CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA

33

Command

Name

Format

Parameter

Remarks

C - Trigger mode

1

Trigger Mode

TR=[Param.]<CR><LF>
TR?<CR><LF>

0=Normal (Continuous)
1=EPS(Edge pre select)
2=PWC(Pulse width control)
3=RCT
5=Smear Less EPS

2

Trigger Polarity

TP=[Param.]<CR><LF>
TP?<CR><LF>

0=Active Low
1=Active High

3

Trigger Input

TI=[Param.]<CR><LF>
TI? <CR><LF>

0=Camera Link
1=Hirose 12pin

D -Image Format

1

Bit Allocation

BA=[Param.]<CR><LF>
BA?<CR><LF>

0=8bit, 1=10bit , 2=12bit

2

Scan Format

SC=[Param.]<CR><LF>
SC? <CR><LF>

0=Full Frame, 1=2/3 Partial
2=1/2 Partial, 3=1/4 Partial
4=1/8 Partial,5= Variable

3

Variable partial

start line

STL=[Param.]<CR><LF>
STL? <CR><LF>

1 to 1024

4

Variable partial

end line

ETL=[Param.]<CR><LF>
ETL? <CR><LF>

8 to 1032

5

V-Binning

VB=[Param.]<CR><LF>
VB?<CR><LF>

0=OFF
1=On

Only CM-
141MCL

E - Gain, Black and signal settings

1

Gain Level

GA=[Param.]<CR><LF>
GA?<CR><LF>

-84 to 670

2

Black Level

BL=[Param.]<CR><LF>
BL?<CR><LF>

255 to 767

F - Saving and loading data in EEPROM

1

Load Setttings

(from Camera

EEPROM)

LD=[Param.]<CR><LF>

0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area

Latest used
DATA AREA
becomes
default at
next power
up.

2

Save Settings

(to Camera

EEPROM)

SA=[Param.]<CR><LF>

1=User 1 area
2=User 2 area
3=User 3 area
Note : 0 is not allowed

3

EEPROM

Current Area No

Request.

EA?<CR><LF>

0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area

The camera
return the
latest used
DATA AREA.

NOTE: Do not try to use commands not shown in this list.