3 pulse width control (pwc) trigge – JAI CB-141MCL User Manual

Page 28

Advertising
background image

CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA

25

LVAL async timing

Fig.27 Edge Pre-select LVAL a-sync Timing

6.3.3 Pulse Width Control (PWC) Trigger Mode

In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to
have a long time exposure. The maximum recommended time is <2 seconds.
The accumulation can be LVAL synchronous or LVAL asynchronous.
The resulting video signal will start to be read out after the trigger rising edge.
For timing details, refer to fig. 20 through fig. 25 and fig.28 and 29.

To use this mode:
Set function: Trigger mode

PWC

Scanning

Full, Partial

Vertical binning

ON / OFF (CM-141MCL only)

Accumulation (Auto)

LVAL sync / LVAL a-sync

Other functions and settings

Input: External trigger

12-pin Hirose or Camera Link

Important notes on using this mode

Trigger pulse width >2LVAL to <2 seconds

The following table shows minimum trigger interval in synchronous accumulation mode

Full scan

1054 L

2/3 Partial

774 L

1/2 Partial

635 L

1/4 Partial

427 L

1/8 Partial

323 L

V Binning

529 L

In the case of asynchronous mode, the exposure time should be added to the above

table.


Advertising
This manual is related to the following products: