2 cm-141 pmcl /-ra and cb-141 pmcl, 3 dip switch sw600 – JAI CB-141MCL User Manual

Page 12

Advertising
background image

CM-141MCL/PMCL/-RA / CB-141MCL/PMCL/-RA

9

5.2.2 CM-141

PMCL /-RA and CB-141

PMCL/-RA










Important Note for PMCL version

CM-141 PMCL/-RA and CB-141 PMCL/-RA cameras feature “Safe Power” circuit which is
stipulated by the PoCL standard. This circuit is used to verify the presence of camera and
PoCL cable before the frame grabber provides power.

5.3 DIP switch SW600

This is for the selection of TTL or 75 ohm
termination for trigger input.
Factory default setting is TTL.
When DIP switch SW600 is changed, at first
remove the top cover. The factory default is
set two switches to OFF position. In order to
set 75 ohm, two switches should be changed to
ON position.

Fig.6. SW-600 DIP switch










Pin No

I/O

Name

Note

1

I

DC +12V

13

I

GND

For # 26 pin

14

I

GND

For # 1 pin

26

I

DC +12V

7(+),20(-)

I/O

RXD

Serial Com.

8(-),21(+)

O

TXD

10(+),23(-)

I

Reserve

9(-),22(+)

I

Trigger

CC1 Ext. Trigger in

6(-),19(+)

O

TxOUT3

Camera Link out

4(-),17(+)

O

TxOUT2

3(-),16(+)

O

TxOUT1

2(-),15(+)

O

TxOUT0

5(-),18(+)

O

TxClk

Clock for CL

Fig.5. Mini-CL
connector

1

2

O

N

TTL

75 Ω

Advertising
This manual is related to the following products: