Connect the Gas Supply

The gas supply line connection is made to the valve
just inside the left rear leg. The gas supply line
should be 3/8" npt with a 1/2" diameter supply, or
the appropriate size to provide sufficient gas pres-
sure to the valve regardless of the input setting.

The use of Flexible Gas Appliance Connectors is

acceptable in many areas in the U.S. However,
Canadian methods vary depending on local code.

ALL INSTALLATIONS MUST COMPLY WITH LOCAL

CODE OR IN THE ABSENCE OF LOCAL CODE, MUST
COMPLY WITH THE MOST RECENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR
CAN-B149.

All codes require a gas shut-off valve (gas cock)

and union, to be installed in the supply line, and in
the same room as the appliance. This allows for the
disconnection of the stove for servicing and mainte-
nance. See Figure 19.

T-HANDLE GAS COCKS ARE REQUIRED IN MASSA-

CHUSETTS IN COMPLIANCE WITH CODE 248CMR.

Secure all joints tightly using appropriate tools

and sealing compounds. For propane units be sure
to use compounds that are propane resistant.Turn
on gas supply and test for gas leaks using a soapy
water solution.

ALWAYS REFER TO THE LIGHTING

INSTRUCTIONS ON THE BACK COVER

OF THIS MANUAL WHEN LIGHTING

YOUR LILLEHAMMER.

Figure 19. Supply Line Shut-off Valve Configurations.

Figure 18. Regulator Assembly.

Mounting
Screws

Regulator Tower

Regulator

Gasket

Conversion
Label

from the front of the valve Regulator. See fig. 18.

13. Remove the regulator tower and the gasket.
14. Install the new variable regulator parts,

confiming that the gasket is properly positioned.
Replace the regulator cover and tighten the three
screws securely.

15. Apply the identification labels to locations as

follows:

• Label A - apply to back of stove.
• Label B - apply to stove’s rating plate.
• Small Conversion Label - apply to valve.

16. Reassemble the stove. Connect supply gas to the

system and check for leaks using a soapy water
solution.

WHEN RE-INSTALLING THE BURNER TUBE, BE SURE
THAT THE TUBE IS PULLED FORWARD IN THE
MOUNTING HOLES AND SECURED WITH THE TWO 1/
4” SCREWS.

NEVER USE AN OPEN FLAME TO

CHECK FOR GAS LEAKS.