Gf 600 dv firelight specifications, Input rates, Suggested tools for installation and service – Jotul GF 600 DV User Manual

Page 4

Advertising
background image

4

GF 600 DV Firelight
Specifications

Input Rates

Natural Gas

40,000 BTU/hr. maximum input
28,600 BTU/hr. minimum input

Propane

40,000 BTU/hr. maximum input
30,900 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)

Propane:

11.0 WC (2.74 kPa) 13.0 WC (3.23 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

1.7 WC (.42 kPa) 3.5 WC (.87 kPa)

Propane:

6.4 WC (1.59 kPa) 10.0 WC (2.49 kPa)

Piezo Ignitor / Standing Pilot
Weight: 260 lbs.

29”

(74 cm)

Top Width

24”

(61 cm)

31”

(79 cm)

28 1/2”

(72.5 cm)

Leg Width

27 3/4”

(70.5 cm)

Exhaust

Outlet

Centerline

31 3/4”

(80.5 cm)

Co-Linear

Transition

Adaptor

Height

Co-linear Adapter (Simpson Dura-Vent #923GCL)
dimensions.

16”

(41 cm)

31 1/8”

(79 cm)

Top Exit
Flue
Collar
Height

Suggested Tools for
Installation and Service

• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve - T-Handle in MA
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10mm open end wrench
• 1/2”, 7/16” open end wrench or deep socket
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• 4 mm allen wrench
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Reciprocating Saw
• Power Drill

THIS FIREPLACE IS SHIPPED FROM THE

FACTORY FOR USE WITH N

N

N

N

NA

A

A

A

ATURAL GAS

TURAL GAS

TURAL GAS

TURAL GAS

TURAL GAS

ONLY. IF USE WITH PROPANE IS DESIRED,

THE APPLIANCE MUST FIRST BE CON-

VERTED USING THE FUEL CONVERSION KIT

PROVIDED, #154391. CONVERSION SHOULD

BE MADE BEFORE THE APPLIANCE IS IN-

STALLED.