Stove and vent clearance requirements – Jotul GF 600 DV User Manual

Page 7

Advertising
background image

7

ALCOVE:
MAXIMUM ALCOVE DEPTH: 24” (61 cm)
MINIMUM ALCOVE WIDTH: 44” (112 cm)
MINIMUM CEILING HEIGHT: 64” (163 mm)

Stove and Vent Clearance
Requirements

Minimum Clearances from the Stove to
Combustibles:
See Figs. 2-4.
Rear:

3” (75 mm)

Ceiling:

33” (840 mm)

Corner:

3” (75 mm)

Right Side: 4” (100 mm)
Left Side: 10” (254 mm)

- for access to Lighting Instruction

plate

Minimum Clearances from the Vent Pipe
to Combustibles:
Horizontal Run:
Off the top of the pipe -

2”(50mm)

Off the sides and bottom -

1”(25mm)

Vertical Run:
All sides

1”(25mm)

* Allow 10” on left side of the appliance for
complete access to the lighting instructions
and control valve.

REAR CLEARANCE = 3” (75 mm)

Left Side*

Right Side

10”

(25.5 cm)

4”

(10 cm)

Figure 3. Parallel Installation Clearances

3” (7.5 cm)

3 ”

(7.5 cm)

3”

7.5 cm

Figure 4. Corner Installation Clearance.

24” or greater depth of ceiling

10” or less in depth

33”

84 cm

29”

74 cm

Figure 2. Mantel and Trim Clearances.