TABLE 23: SUPPLY AIR BLOWER PERFORMANCE (BQ060 BELT DRIVE) - SIDE DUCT APPLICATION

Air

Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard Drive Option

HIgh Static Drive Option

1200

680

0.47

781

0.52

874

0.58

960

0.65

1041

0.72

1115

0.80

1185

0.88

1251

0.96

1314

1.05

1375

1.14

1400

706

0.56

807

0.61

901

0.67

987

0.73

1067

0.80

1142

0.88

1212

0.96

1278

1.05

1341

1.13

1401

1.22

1600

737

0.67

839

0.72

932

0.77

1018

0.84

1098

0.91

1173

0.99

1243

1.07

1309

1.15

1372

1.24

1433

1.33

1800

774

0.80

875

0.85

968

0.90

1055

0.97

1135

1.04

1209

1.12

1279

1.20

1345

1.28

1408

1.37

1469

1.46

2000

815

0.95

916

1.00

1010

1.06

1096

1.12

1176

1.19

1251

1.27

1321

1.35

1387

1.44

1450

1.52

1510

1.61

2200

862

1.12

963

1.17

1056

1.23

1142

1.29

1223

1.36

1297

1.44

1367

1.52

1433

1.61

1496

1.70

1557

1.78

2400

913

1.31

1014

1.36

1107

1.42

1194

1.49

1274

1.56

1349

1.63

1419

1.72

1485

1.80

1548

1.89

1608

1.98

2600

969

1.52

1070

1.57

1163

1.63

1250

1.70

1330

1.77

1405

1.84

1475

1.93

1541

2.01

1603

2.10

1664

2.19

TABLE 24: SUPPLY AIR BLOWER PERFORMANCE (BQ060 BELT DRIVE) - BOTTOM DUCT APPLICATION

Air

Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard Drive Option

HIgh Static Drive Option

1200

663

0.48

773

0.53

875

0.59

969

0.65

1056

0.72

1138

0.80

1214

0.88

1286

0.96

1354

1.04

1420

1.13

1400

692

0.57

802

0.61

904

0.67

998

0.73

1085

0.80

1167

0.88

1243

0.96

1315

1.04

1383

1.13

1449

1.21

1600

726

0.67

836

0.72

938

0.78

1032

0.84

1119

0.91

1201

0.98

1277

1.06

1349

1.15

1417

1.23

1483

1.32

1800

766

0.80

876

0.85

977

0.90

1072

0.97

1159

1.04

1240

1.11

1316

1.19

1388

1.27

1457

1.36

1523

1.45

2000

811

0.95

921

0.99

1023

1.05

1117

1.11

1204

1.18

1285

1.26

1362

1.34

1434

1.42

1502

1.51

1568

1.59

2200

861

1.11

971

1.16

1073

1.22

1167

1.28

1255

1.35

1336

1.43

1412

1.51

1484

1.59

1553

1.68

1619

1.76

2400

917

1.30

1027

1.35

1129

1.41

1223

1.47

1311

1.54

1392

1.62

1468

1.69

1540

1.78

1609

1.86

1675

1.95

2600

978

1.51

1088

1.56

1190

1.61

1284

1.68

1371

1.75

1453

1.82

1529

1.90

1601

1.98

1670

2.07

1736

2.15

Field Supplied Drive

TABLE 25: SUPPLY AIR BLOWER PERFORMANCE (BQ036, 048 & 060 DIRECT DRIVE) -

SIDE DUCT APPLICATION

UNIT

TONNAGE

MOTOR

1

SPEED

AVAILABLE EXTERNAL STATIC PRESSURE - IWG

2

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

CFM

WA

T

T

S

3

3

HI

-

-

-

-

-

-

1720

825

1665

795

1600

765

1540

735

1490

700

1380

670

MED

1660

850

1630

820

1590

780

1550

750

1500

720

1450

690

1400

665

1360

650

1270

610

LOW

1470

750

1440

725

1410

700

1370

675

1330

650

1290

625

1250

610

1220

600

1130

560

4

3

HI

-

-

-

-

2000

1010

1950

975

1905

945

1840

910

1770

825

1660

825

1530

775

MED

1810

910

1780

880

1740

850

1700

825

1665

800

1620

775

1560

740

1480

700

1390

660

LOW

1635

810

1610

780

1580

760

1555

740

1540

730

1510

715

1460

690

1400

660

1300

615

5

3

HI

-

-

-

-

2500

1400

2420

1350

2340

1300

2260

1250

2160

1190

2060

1135

1925

1065

MED

2390

1350

2350

1300

2300

1255

2245

1210

2190

1165

2130

1120

2065

1075

1990

1030

1900

970

LOW

2270

1320

2230

1270

2190

1220

2145

1170

2090

1110

2030

1070

1960

1020

1890

970

1810

920

1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil, 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
3. Side Flow application (230/460/575 Volts)

Advertising
This manual is related to the following products: