TABLE 26: SUPPLY AIR BLOWER PERFORMANCE (BQ036, 048 & 060 DIRECT DRIVE) -

BOTTOM DUCT APPLICATION

UNIT

TONNAGE

MOTOR

1

SPEED

AVAILABLE EXTERNAL STATIC PRESSURE - IWG

2

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

3

3

HI

-

-

-

-

-

-

1661

825

1608

795

1545

765

1487

735

1439

700

1333

670

MED

1603

850

1574

820

1535

780

1497

750

1449

720

1401

690

1352

665

1314

650

1227

610

LOW

1420

750

1391

725

1362

700

1323

675

1285

650

1246

625

1208

610

1179

600

1092

560

4

3

HI

-

-

-

-

1931

1010

1882

975

1839

945

1776

910

1709

825

1603

825

1478

775

MED

1748

910

1719

880

1680

850

1641

825

1608

800

1564

775

1507

740

1429

700

1343

660

LOW

1579

810

1555

780

1526

760

1502

740

1487

730

1458

715

1410

690

1352

660

1256

615

5

3

HI

-

-

-

-

2412

1400

2335

1350

2258

1300

2181

1250

2085

1190

1988

1135

1858

1065

MED

2306

1350

2268

1300

2220

1255

2167

1210

2114

1165

2056

1120

1993

1075

1921

1030

1834

970

LOW

2191

1320

2152

1270

2114

1220

2070

1170

2017

1110

1960

1070

1892

1020

1825

970

1748

920

1. Factory set on medium speed tap.
2. Includes allowances for a wet evaporator coil, 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
3. Side Flow application (230/460/575 Volts)

TABLE 27: BELT DRIVE RPM SELECTION

Size

(Tons)

HP

Max

BHP

Motor

Sheave

Blower

Sheave

5 Turns

Open

4 Turns

Open

3 Turns

Open

2 Turns

Open

1 Turn

Open

Fully

Closed

036

(3)

1.5

1.73

1VL44

AK64

805

865

920

980

1035

1095

1.5

1.73

1VP56

AK66

1115

1170

1225

1280

1335

1390

048

(4)

1.5

1.73

1VL44

AK56

930

995

1060

1130

1195

1260

1.5

1.73

1VP56

AK61

1210

1270

1330

1390

1455

1515

060

(5)

1.5

1.73

1VL44

AK56

930

995

1060

1130

1195

1260

2

2.3

1VP56

AK56

1325

1395

1460

1525

1590

1660

TABLE 28: BELT DRIVE BLOWER MOTOR AND DRIVE DATA

Size

(Tons)

Motor

Motor Sheave

Blower Sheave

Belt

HP

RPM

Eff.

SF

Frame

Datum Dia.

(in.)

Bore (in.)

Model

Datum Dia.

(in.)

Bore (in.)

Model

036

(3.0)

1-1/2

1725

0.8

1.15

56

2.8 - 3.8

7/8

1VL44

6.0

1

AK64

A37

1-1/2

1725

0.8

1.15

56

4.0 - 5.0

7/8

1VP56

6.2

1

AK66

A39

048

(4.0)

1-1/2

1725

0.8

1.15

56

2.8 - 3.8

7/8

1VL44

5.2

1

AK56

A36

1-1/2

1725

0.8

1.15

56

4.0 - 5.0

7/8

1VP56

5.7

1

AK61

A38

060

(5.0)

1-1/2

1725

0.8

1.15

56

2.8 - 3.8

7/8

1VL44

5.2

1

AK56

A36

2

1725

0.8

1.15

56

4.0 - 5.0

7/8

1VP56

5.2

1

AK56

A38

TABLE 29: STATIC RESISTANCES

Description

Resistance, IWG

CFM

1000

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

Economizer

1

2

1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables.
2. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air

duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

0.30

Electric

Heaters

1

7 - 15 kW

0.04

0.05

0.06

0.07

0.08

0.10

0.12

0.14

0.16

0.19

0.22

20 - 30 kW

0.06

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

Bottom Duct Connections

1

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.14

0.16

0.19

0.22