Instructions f, Heating elements rating – John Lewis JLBIGH601 User Manual

Page 6

Advertising
background image

6

BURNER

BURNER

BURNER

BURNER

BURNER

RAPID

RAPID

RAPID

RAPID

RAPID

SEMI-RAPID

SEMI-RAPID

SEMI-RAPID

SEMI-RAPID

SEMI-RAPID

A U X I L I A R Y

A U X I L I A R Y

A U X I L I A R Y

A U X I L I A R Y

A U X I L I A R Y

(large)

(large)

(large)

(large)

(large)

(medium)

(medium)

(medium)

(medium)

(medium)

(small)

(small)

(small)

(small)

(small)

P O S I T I O N

P O S I T I O N

P O S I T I O N

P O S I T I O N

P O S I T I O N

M A X

M A X

M A X

M A X

M A X

M I N

M I N

M I N

M I N

M I N

M A X

M A X

M A X

M A X

M A X

M I N

M I N

M I N

M I N

M I N

M A X

M A X

M A X

M A X

M A X

M I N

M I N

M I N

M I N

M I N

NOMINAL THERMAL
POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE m

3

/h

0.286

0.057

0.190

0.043

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust

NOMINAL THERMAL
POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW
RATE g/h

202

47

144

32

72

24

NOZZLE REFERENCE

86

40

71

32

50

28

OVERALL DIMENSIONS

OVERALL DIMENSIONS

OVERALL DIMENSIONS

OVERALL DIMENSIONS

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

CUT OUT DIMENSIONS

CUT OUT DIMENSIONS

CUT OUT DIMENSIONS

CUT OUT DIMENSIONS

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

SUPPLY CONNECTIONS

SUPPLY CONNECTIONS

SUPPLY CONNECTIONS

SUPPLY CONNECTIONS

SUPPLY CONNECTIONS

G a s :

G a s :

G a s :

G a s :

G a s :

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

Electric:

Electric:

Electric:

Electric:

230V 50Hz supply, 3 core flexible cable with non rewireable
plug fitted with a 3 amp cartridge fuse.

Heating Elements Rating

Heating Elements Rating

Heating Elements Rating

Heating Elements Rating

Heating Elements Rating

Rear Left Burner (semi ra

Rear Left Burner (semi ra

Rear Left Burner (semi ra

Rear Left Burner (semi ra

Rear Left Burner (semi rapid)

pid)

pid)

pid)

pid)

Heat Input

2.0 kW

Fr

Fr

Fr

Fr

Front Left Burner (ra

ont Left Burner (ra

ont Left Burner (ra

ont Left Burner (ra

ont Left Burner (rapid)

pid)

pid)

pid)

pid)

Heat Input

3.0 kW

Rear Right Burner (semi ra

Rear Right Burner (semi ra

Rear Right Burner (semi ra

Rear Right Burner (semi ra

Rear Right Burner (semi rapid)

pid)

pid)

pid)

pid)

Heat Input

2.0 kW

Fr

Fr

Fr

Fr

Front Right Burner (auxiliar

ont Right Burner (auxiliar

ont Right Burner (auxiliar

ont Right Burner (auxiliar

ont Right Burner (auxiliary)

y)

y)

y)

y)

Heat Input

1.0 kW

Burner

Burner

Burner

Burner

Burner

Dia. Tap By-pass

Dia. Tap By-pass

Dia. Tap By-pass

Dia. Tap By-pass

Dia. Tap By-pass

1/100 mm

1/100 mm

1/100 mm

1/100 mm

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

NATURAL GASNATURAL GASNATURAL GASNATURAL GASNATURAL GAS

20 mbar20 mbar20 mbar20 mbar20 mbar

TYPE OFTYPE OFTYPE OFTYPE OFTYPE OF

GASGASGASGASGAS

CHARACTERISTICS

LPG GASLPG GASLPG GASLPG GASLPG GAS

28-30/37 mbar28-30/37 mbar28-30/37 mbar28-30/37 mbar28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

Instructions f

Instructions f

Instructions f

Instructions f

Instructions for the Installer

or the Installer

or the Installer

or the Installer

or the Installer

T

T

T

T

Technical data

echnical data

echnical data

echnical data

echnical data

APPLIANCE CLASS

APPLIANCE CLASS

APPLIANCE CLASS

APPLIANCE CLASS

APPLIANCE CLASS:

3

APPLIANCE C

APPLIANCE C

APPLIANCE C

APPLIANCE C

APPLIANCE CA

A

A

A

ATEGOR

TEGOR

TEGOR

TEGOR

TEGORY

Y

Y

Y

Y:

II2H3+

APPLIANCE GAS SUPPL

APPLIANCE GAS SUPPL

APPLIANCE GAS SUPPL

APPLIANCE GAS SUPPL

APPLIANCE GAS SUPPLY

Y

Y

Y

Y:

Natural gas G20 / 20mbar

Advertising