Fault finding – John Lewis JLBIGH601 User Manual

Page 9

Advertising
background image

9

Fault Finding

Fault Finding

Fault Finding

Fault Finding

Fault Finding

Y E S

Y E S

Y E S

Y E S

Y E S

Check plug top fuse and
replace if necessary

Check polarity and earth
continuity of supply point

Check earth continuity
of appliance

Does ignitor spark?

Check fitting of burners

Check position of the
electrode

Check by pass simmer
adjusted

Light burner manually

Check gas supply at
burner

Check continuity from 'N' on the
mains connector block and "N" on
the ignitor unit

Check continuity from 'L' on the
mains connector block and the
taps ignition switches

Check continuity from ignition
switches connector to ignitor unit “L”

Check continuity from the tip of
each electrode to the terminals 1
to 4 on the ignitor unit

Check for breaks in the insulation
of the HT leads

Change the taps ignition
switches

N O

N O

N O

N O

N O

Change the ignitor unit