Wiring diagram – John Lewis JLBIGH601 User Manual

Page 8

Advertising
background image

8

1. IGNITOR SWITCHES

1. IGNITOR SWITCHES

1. IGNITOR SWITCHES

1. IGNITOR SWITCHES

1. IGNITOR SWITCHES

2. IGNITOR UNIT

2. IGNITOR UNIT

2. IGNITOR UNIT

2. IGNITOR UNIT

2. IGNITOR UNIT

Wiring Diagram

Wiring Diagram

Wiring Diagram

Wiring Diagram

Wiring Diagram

Fault Finding

Fault Finding

Fault Finding

Fault Finding

Fault Finding

Pr

Pr

Pr

Pr

Preliminar

eliminar

eliminar

eliminar

eliminar y Electrical Systems

y Electrical Systems

y Electrical Systems

y Electrical Systems

y Electrical Systems

Check

Check

Check

Check

Check

A.

A.

A.

A.

A. EAR

EAR

EAR

EAR

EARTH CONTINUITY CHECK

TH CONTINUITY CHECK

TH CONTINUITY CHECK

TH CONTINUITY CHECK

TH CONTINUITY CHECK - Appliance

must be electrically disconnected - meter set on W
(Ohms) x 1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1 W
(Ohm), check all earth wires for continuity and all
contacts are clean and tight.

B.

B.

B.

B.

B. INSULA

INSULA

INSULA

INSULA

INSULATION CHECK

TION CHECK

TION CHECK

TION CHECK

TION CHECK - Appliance electrically

disconnected, all switches ON.
a) meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.

b) meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads
less than ¥ (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but
no fault is indicated - a detailed continuity check (i.e.
by disconnecting and checking each component) is
required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should reveal
evidence of burning around the fault.

START

START

START

START

START
Isolate appliance
and carry out:
A:

A:

A:

A:

A: Earth Continuity
check.

Has inlet fuse blown?

Carry out:
B:

B:

B:

B:

B: Insulation check.

Electricity supply
should now be
satisfactory.

Inlet wiring
faulty.
Rectify any
fault.

Isolate appliance and
carry out:
B:

B:

B:

B:

B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.

Brown

Blue

Green
Yellow

Green
Yellow

Brown

Blue

NO

NO

NO

NO

NO

Y E S

Y E S

Y E S

Y E S

Y E S

NO

NO

NO

NO

NO

Y E S

Y E S

Y E S

Y E S

Y E S

L

N

0

220

240

1
2
3
4

1

2