At-140ge – JAI AT-140GE User Manual
Page 31
AT-140GE
- 29 -
Fig.23 Variable Partial scan
How to calculate total line number and frame rate in variable partial scan mode
Frame rate (fps) = Horizontal frequency(21.938KHz) / Total lines
Total lines = ①OB period + ②Fast Dump period in the upper part of the frame (L) +
③
Effective image period (L) + ④Fast dump period in the lower part of frame
(L) + ⑤Blank period (L)
Where,
OB period = 4L (Fixed)
Blank period = 6L (Fixed)
Fast dump period for the upper part =
Round up
4+Start line −1
4
+ 1
Fast dump period for the lower part =
Roud up
1040−End line +2
4
Calculation example
Readout: 1/2 partial scan at the center (520L), Start line (261), End line (780)
OB period = 4L
Blank period =6L
Fast dump period for the upper part = (4+261-1) ÷4 +1= 66 + 1=67 67
Fast dump period for the lower part = (1040-780+2) ÷ 4 =65.5 66
Total lines = 4+67+520+66 +6 = 663
Frame rate = 21.938/ 663 =33.08 fps
Image Height
Image start line
/ end line
Minimum: 8 line
Maximum: 1040 lines
Image starts at 1st line
Image starts at 1033rd line
This is in case image height is 8 line
1/8
1033
/1040
8 line
1040 lines