At-140ge – JAI AT-140GE User Manual

Page 67

Advertising
background image

AT-140GE

- 65 -

LUT Controls

Address

Display Name
(JAI Control Tool)

GenICam name

Read /
Write

Size Value / Range of value

Description

Default
value

0xA200

LUT Enable

LUTEnable

R
W

4

0xD000
|
0xD7FC

LUT Value (Red)

LUTValue[Red]

R
W

4

0 ~ 65535

0

0xD800
|
0xDFFC

LUT Value(Green,Bayer or
Monochrome)

LUTValue[Green]

R
W

4

0 ~ 65535

0

0xE000
|
0xD7FC

LUT Value (Blue)

LUTValue[Blue]

R
W

4

0 ~ 65535

0

Event Generation

Address Display Name

(JAI Control Tool)

GenICam name

Read /
Write

Size Value / Range of value

Description

Default
value

0xA610

Event Selector
Acquisition Trigger



GevEventtreigger

RW

4

Selector Value
0

Event message ON/OFF

0

Exposure Start

GevEventStartOfExposure

1

0

Exposure End

GevEventEndOfExposure

2

0

Frame Transfer Start

GevEventStartOfTransfer

3

0

Frame Transfer End

GevEventEndOfTransfer

4

0

Any Lines Any Edges

AnyLineAynyEdge

17

0

Updated All Features

UpdatedAllFeatures

18

1

Processing Done

ProcessingDone

19

1

Video Parameters
Changed

VideoParamsChanged

20

1

Opposite Channel
Parameters changed

DioTrigParamsChanged

21

1

Device Reset

DeviceReset

31

1

Event Notification

EventNotification

0=Disable
1=Enable

User Sets

Address Display Name

(JAI Control Tool)

GenICam name

Read /
Write

Size Value / Range of value

Description

Default
value

0xA300

User Set Save

UserSetSave

W

4

1=User area1

Allows use to save all
camera settings. Last
used area number
becomes new default.

1

0xA304

User Set Load

UserSetLoad

W

4

0=Factory area
1=User area1

Allow the user to recall
all camera settings.

0

0xA308

User Set Selector

UserSetSelector

RW

4

When receiving
following commands,
store the parameters
0xA300
0xA304

Check the used data,
0=Factory or1=User

0