4 reset continuous trigger (rct), At-140ge – JAI AT-140GE User Manual

Page 47

Advertising
background image

AT-140GE

- 45 -

9.7.4 Reset Continuous Trigger (RCT)
The RCT mode operates like EPS (Edge Pre-select) mode with smearless function. An
external trigger pulse will immediately stop the video read out, reset and restart the
exposure, then operate as normal mode until the next trigger. After the trigger pulse is
input, a fast dump read out is performed. In the AT-140GE, this period is 16.04ms which is
352L. The exposure time is determined by the pre-set shutter speed. If no further trigger
pulses are applied, the camera will continue in normal mode and the video signal is not
output. The fast dump readout has the same effect as “smearless readout”. Smear above
bright areas is reduced for the trigger frame. The reset continuous trigger mode makes it
possible to use triggering in conjunction with a lens with video controlled iris.
RCT mode is available only in LVAL asynchronous.

To use this mode:
Set function:

Exposure mode

RCT

Pixel format

RGB 8, 10V1, 10V2

Partial scan

Fast Dump ON, ROI

Vertical binning

Binning vertical ON

Shutter mode

Programmable, Exposure Time Abs

GPIO settings

Important notes on using this mode

 Active Trigger pulse >2 LVAL to <1 FVAL
 Minimum Trigger interval is shown in the following table.

Mode

Minimum trigger interval

LVAL Async

Smearless time(265L) + Maximum exposure time +1252L + 3L

Note: 1) On the above table, 1252L is FVAL interval on normal continuous mode
2) In the vertical binning mode, 1L is different from the normal scanning. So, the minimum

trigger interval will be different.

Fig.47 RCT mode

Note: In this mode, if the next trigger is input while the data is read out, the data can be immediately transferred.

The minimum trigger interval should be kept.

D V A L

D A T A O U T

Co n t i n u o u s Da t a

T r i g g e r e d Da t a

Co n t i n u o u s Da t a

L V A L

S U B

S G

F V A L

E x t . T r i g

Camer a Li nk

Hi g h S peed

Tr a ns f er

Mi n . 2 L

E E N

E x p o s u r e

P e r i o d

X E E N

(Hirose 12pi n)

Smear less (352L)

1L=1958 Clock (45.58 μs)

Advertising