At-140ge – JAI AT-140GE User Manual

Page 56

Advertising
background image

AT-140GE

- 54 -

Specifications

AT-140GE

Functions controlled via GigE
Vision Interface

Shutter, gain, black Level, trigger mode, readout mode,

GPIO setup, ROI (GenICam mandatory functions)

GigE Vision Streaming Control

Packet size, delayed (frame) readout, inter-packet delay

Jumbo frame can be set at max. 16K (16020), default packet size is 1476 bytes.

Operating temperature

-5

C to +45

C.

Humidity

20 - 80% non-condensing

Storage temp./humidity

-25

C to 60

C./20% - 80% non-condensing

Vibration

3 G (15 Hz – 200 Hz in XYZ)

Shock

50 G

Regulations

CE (EN 61000-6-2, EN 61000-6-3), FCC part 15 class B, RoHS

Power

10.8V to 26.4V DC. 0.61 A (Typical , Full frame ,12V input)

0.68 A (Typical ,1/8 partial, +12V input)

Lens mount

C-mount (Rear protrusion on C mount must be less than 4mm)

The lens used should be designed for 3CCD cameras.

Flange back

17.526mm, Tolerance +0 to –0.05mm

Optical axis

Center

0.1mm

Dimensions

55 x 55 x 98.3 mm (HxWxD)

Weight

320g


Note: 1) Partial scan and vertical binning can not be used at the same time. Partial scan has priority.

2) Above specifications are subject to change without notice

3)

Specifications are valid after a 30 min. warm up period.




























Advertising