Installation

Warning!
• This appliance must be installed by

a qualified electrician/competent
person. Safety may be impaired if
installation is not carried out in
accordance with these instructions.

• This appliance must be earthed.
• Do not remove the screws from the

earth tab extending from the oven
mains terminal block.

• Before connecting the appliance

make sure that the voltage of your
electricity supply is the same as that
indicated on the rating plate. This is
situated on the lower front frame of
the appliance and can be seen upon
opening the door. Alternatively the
rating plate may also be found on
the back or top of some models
(where applicable).

• Do not alter the electrical circuitry

of this appliance.

Things to note

• This appliance is designed to be fitted in

cabinets of the recommended dimensions
as shown.

• If your cabinet interior dimension is

between 565-570mm the oven may still be
fitted. However, a minor modification to
the cabinet will be required to reduce the
aperture size down to 560-565mm, to
allow the product to be securely screwed
into the cabinet.

• The dimensions given provide adequate air

circulation around the unit within the
cabinet, ensuring compliance with BS
EN60-335.

• Enquiries regarding the installation of the

cooker point, if required, should be made
to your Regional Electricity Company to
ensure compliance with their regulations.

• The appliance socket switch should be

outside the cabinet but within 2m of the
appliance to make it accessible to switch off
the appliance in case of an emergency.

• To protect the hands, wear gloves when

lifting the oven into its housing.

Warning! Do not lift the appliance by
the handles.

Important! House circuit
Earth leakage and continuity tests must be
carried out before the appliance is connected
to the mains supply and re-checked after
fitting.

Choice of electrical
connection

• The appliance should be operated using at

least 6mm2 twin core and earth PVC
insulated mulit core cable. Please choose
from the most appropriate after reading the
different methods:-

41