7

Connecting to the mains
terminal

Warning

This appliance must be earthed.

We recommend you use a new length of 6mm2 twin

core and earthed cable to ensure your safety.

Make connection as shown below by proceeding as

follows: -

Pre-form wires to the appropriate shape to suit fitting

into the mains terminal block.

Strip inner insulation on wires using wire strippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from the end of the inner

insulation. Where un-insulated Earth wires are used

ensure they are suitably sheathed to leave 10mm bare

wire to fit into the terminal.

Clamp bare wires into the relevant terminal and check

they are held by tugging each one in turn.

Clamp the mains cable securely ensuring 5mm of the

outer insulation is inside the terminal block and that

the wires are not taught but not so slack as to cause

any fouling.

Place fuse/miniature circuit breaker in circuit and

switch on at mains.



Checking electrical
connections

Correct electrical connection can be confirmed when switching

on the appliance, as the timer will be flashing.

Connecting to a hob or cooker
point

Either follow in general terms the instructions for

connecting to the terminal block or refer to the hob

suppliers installation instructions.

Warning

Feed the cable through the cabinet and arrange to

route the cable away from the appliance which may

become hot.