Juniper Networks EX4200 User Manual

Page 42

Advertising
background image

Table 4: LCD Panel Menu Options in EX3200 and EX4200 Switches (continued)

Description

Menu

The Maintenance menu has the following options to configure and troubleshoot the switch:

SYSTEM HALT?—Select this option using the

Enter

button to halt the switch. Press the

Enter

button again

to confirm the halt. Press the

Menu

button to go to the next option in the Maintenance menu.

SYSTEM REBOOT?—Select this option using the

Enter

button to reboot the switch. Press the

Enter

button

again to confirm the reboot. Press the

Menu

button to go to the next option in the Maintenance menu.

LOAD RESCUE?—Select this option using the

Enter

button to roll back the switch to the rescue

configuration. Press the

Enter

button again to confirm the rollback. Press the

Menu

button to go to the

next option in the Maintenance menu.

REQUEST VC PORT?—Select this option using the

Enter

button to configure an uplink module port or an

EX4200-24F network port to be a Virtual Chassis port (VCP) or to delete a VCP from the switch
configuration (when you delete the VCP, the port is reset to an uplink module port or an EX4200-24F
network port).

For information on how to use the REQUEST VC PORT option, see Setting an Uplink Module Port or an
EX4200-24F Network Port as a Virtual Chassis Port Using the LCD Panel.

FACTORY DEFAULT?—Select this option using the

Enter

button to restore the switch to the factory default

configuration. Press the

Enter

button again to confirm the restoration. Press the

Menu

button to go to

the next option in the Maintenance menu.

ENTER EZSETUP?—Select this option using the

Enter

button to launch EZSetup. Press the

Enter

button

again to confirm the launch. Press the

Menu

button to go to the next option in the Maintenance menu.

You can use the ENTER EZSETUP option only if the switch is in the factory default configuration.

For information about EZSetup, see “Connecting and Configuring an EX Series Switch (J-Web Procedure)”
on page 163.

EXIT MAINT MENU?—Select this option to exit the Maintenance menu.

You can disable the Maintenance menu in the LCD panel. See “Configuring the LCD Panel Display on EX
Series Switches (CLI Procedure)” on page 166.

MAINT
(Maintenance
Menu)

Related Topics

Front Panel of an EX3200 Switch on page 8

Front Panel of an EX4200 Switch on page 10

Field-Replaceable Units in EX3200 and EX4200 Switches on page 16

Connecting and Configuring an EX Series Switch (CLI Procedure) on page 161

Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 163

Field-Replaceable Units in EX3200 and EX4200 Switches

Field-replaceable units (FRUs) are components that you can replace at your site. The
field-replaceable units (FRUs) in EX3200 and EX4200 switches are:

Power supply

Fan tray

Uplink module

SFP transceiver

16

Field-Replaceable Units in EX3200 and EX4200 Switches

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches