18.1. Enhanced Baud Rate Generation

The UART0 baud rate is generated by Timer 1 in 8-bit auto-reload mode. The TX clock is generated by
TL1; the RX clock is generated by a copy of TL1 (shown as RX Timer in Figure 18.2), which is not
user-accessible. Both TX and RX Timer overflows are divided by two to generate the TX and RX baud
rates. The RX Timer runs when Timer 1 is enabled, and uses the same reload value (TH1). However, an
RX Timer reload is forced when a START condition is detected on the RX pin. This allows a receive to
begin any time a START is detected, independent of the TX Timer state.

Figure 18.2. UART0 Baud Rate Logic

Timer 1 should be configured for Mode 2, 8-bit auto-reload (see

Section “21.1.3. Mode 2: 8-bit Counter/

Timer with Auto-Reload” on page 237

). The Timer 1 reload value should be set so that overflows will

occur at two times the desired UART baud rate frequency. Note that Timer 1 may be clocked by one of six
sources: SYSCLK, SYSCLK / 4, SYSCLK / 12, SYSCLK / 48, the external oscillator clock / 8, or an exter-
nal input T1. For any given Timer 1 clock source, the UART0 baud rate is determined by Equation 18.1.

Equation 18.1. UART0 Baud Rate

Where T1

CLK

is the frequency of the clock supplied to Timer 1, and T1H is the high byte of Timer 1 (reload

value). Timer 1 clock frequency is selected as described in

Section “21. Timers” on page 235

. A quick

reference for typical baud rates using the internal oscillator is given in Table 18.1. Note that the internal
oscillator may still generate the system clock if an external oscillator is driving Timer 1.

18.2. Operational Modes

UART0 provides standard asynchronous, full duplex communication. The UART mode (8-bit or 9-bit) is
selected by the S0MODE bit (SCON0.7). Typical UART connection options are shown below.

RX Timer

Start

Detected

Overflow

Overflow

TH1

TL1

TX Clock

2

RX Clock

2

Timer 1

UART

UartBaudRate

T1

CLK

256

T1H

-------------------------------

1
2

---

=