Tilt stop collars – Woodstock SHOP FOX W1824 User Manual

Page 60

Advertising
background image

Df[\cN(/)+('?pYi`[KXYc\JXn

-58-

J<I

M

@:<

Tilt Stop Collars

The table saw features stop collars that halt the blade tilt
exactly at 45° and 90°. The stop collars have been set at
the factory and should require no adjustments, unless you
notice that your cuts are not accurate.

Note: The tilt scale reads "0" when the blade is 90° to the
table.

Tools Needed

Qty

90° Square .......................................................1
45° Square .......................................................1
Hex Wrench 4mm ...............................................1

Setting 90° Stop Collar

1. DISCONNECT SAW FROM POWER!

2. Raise the blade as high as it will go, then tilt it

toward 0° until it stops and cannot be tilted any
more.

3. Place a 90° square against the table and blade so

it contacts the blade evenly from bottom to top,
as shown in Figure 88. Make sure the square is not
contacting a blade tooth.

Note: If adjustments are made to the 90° stop
collar in the following steps, make sure the tilt
indicator arrow shown in Figure 89 points to the
0° mark on the scale when the table is at 90°
with the blade. If it is not, loosen the button head
screw that secures the indicator, then adjust it and
re-tighten the screw.

— If the blade is 90° to the table, then adjustments

do not need to be made.

— If the blade is not 90° to the table, adjust the 90°

stop collar and proceed to the next step.

4. Tilt the blade away from 0° by about 5°, so there is

room for the 90° stop collar to move.

5. Open the motor access cover, loosen the cap screws

shown in Figure 90, then thread the 90° stop collar
one turn away from the trunnion bracket. This will
allow you to square the blade in the next step.

KXYc\

0'—JhlXi\

9cX[\

Figure 88. Checking the blade at 90°.

Figure 89. Tilt indicator and scale.

Tilt Indicator

at 0°

Figure 90. 90° stop collar and cap screws.

Trunnion

Bracket

90° Stop Collar

Cap Screws

Advertising