Sterling STT 1600 User Manual

Page 42

Advertising
background image

Check the blo wer.
Va cu um sen sor de fec ti ve.

Tem pe ra tu re Mea su re ment Re ge ne ra ti on Hea ter De fec ti ve
Check the ca bles and the sen sor.
Check the po wer supp ly.
Short cir cuit check.

Ex cess Tem pe ra tu re Re ge ne ra ti on Hea ter
The re ge ne ra ti on tem pe ra tu re is too high.

Check the sa fe ty tem pe ra tu re li mi ter.
Ster ling Ser vi ce.

In suf fi cient Tem pe ra tu re Re ge ne ra ti on Hea ter
The re ge ne ra ti on tem pe ra tu re is too low.

Check the re ge ne ra ti on hea ter.

The Sa fe ty Switch Re ge ne ra ti on Hea ter Has Been Ac tua ted
Check the hea ter.
Check the fu ses.
Short cir cuit check of the hea ter.

Er ror By pass Flap
The by pass flap does not clo se or clo ses too slowly.

Check the by pass flap.

Er ror Val ve Block
The val ve block has not rea ched the pro per po si ti on. The main switch is pla ced in the off po si ti on.

Check the po si ti on of the val ve block. Press the “ACK” key and put the main switch in the on po si ti -
on im me di ate ly. If the val ve block has not rea ched the cor rect po si ti on wit hin 1 mi nu te, the main
switch is again pla ced in the off po si ti on.

Ster ling Ser vi ce.

Tem pe ra tu re Mea su re ment Out going Air De fec ti ve
Check ca bles and sen sor.

Tem pe ra tu re Mea su re ment Re turn Air De fec ti ve
Check ca bles and sen sor.

Ex cess Tem pe ra tu re Re turn Air
Check ca bles and sen sor.
Check the re turn air coo ler.

0

3

6-

2

M

S

De hu mi di fied Air Dry er

Er ror and er ror cor rec ti on 4-7

Advertising