Errors 017 to 019

· AFI fault current

The error «AFI fault current» occurs if fault

current has penetrated the PV system and

the Solar Inverter has subsequently discon-

nected from the grid. The earth fault is

monitored on the AC and on the DC side

(universal current sensitive FI). If this error

message occurs, the entire PV system must

be checked for insulation faults. The func-

tioning method complies with E DIN VDE

0126-1-1. In case of fault current at inlet 1

of the PV generator, for example, «error

017» will be flagged.

Errors 020 to 022

· Insulation faults

Prior to start-up, your Solar Inverter always

checks the PV system for an earth fault or

an insulation fault. Should such a fault be

detected, the injection will not start. The

functioning method complies with E DIN

VDE 0126-1-1. In case of an insulation fault

at inlet 2 of the PV generator, for example,

«error 021» will be flagged.

Errors 023 to 025

· DC injection

Your Solar Inverter continuously monitors

the quality of the injected electricity. If an

increased share of DC current is detected in

the injected electricity, the Solar Inverter

will stop the injection The Solar Inverter

will only try to continue the injection after

the system has been shut down and restar-

ted manually, or automatically the next

day.

Error 026

· Isolated operation

Your Solar Inverter is equipped with a

high-quality redundant grid monitoring

system that complies with E DIN VDE

0126-1-1 and continuously monitors the

grid. If one of the monitoring phases fails,

or if the phase relation changes between

the individual conductors, the Solar

Inverter will stop the injection and only

restart when the error has been elimina-

ted, i. e. when the AC grid works properly

again.