25. Remove the two doctor blade screws and the doctor blade. Note the clear plastic strip that covers the DB screws. Slide the
screwdriver under the strip. Be careful not to damage the strip!

26. Remove the fill plug and clean out all the remaining toner
in the supply hopper

27. Note the magnetic seals on the MRS and the DB sealing
foam. Make sure both are clean.