OPERATION

Prior to drinking water from the unit, flush unit for five minutes.

To operate the unit, simply turn on the cold water faucet and pull the

diverter valve plunger outward (Figure 11). To

bypass the unit, push the diverter valve inward.

You will observe the following when the

Sterilight unit is operating properly:

1. Once flow is established, the UV lamp will

turn on and become fully bright and steady

within the first second of operation.

2. Water enters the unit at the bottom where it

is mixed with ozone, forming a Sterilight of

swirling bubbles and a swooshing sound.

3. Any ozone left following the patented

ozone/UV photo-oxidation process is reconverted to oxygen in the

filter element. Water leaving the unit is fully treated and mixed

with air and the reconverted ozone. The air will appear as tiny

bubbles, sometimes giving the water an initial cloudy appearance.

After sitting for a minute or so,

all of the bubbles will rise to the surface and disperse, leaving the

water crystal clear.

4. Because of the trapped air, the water outlet from the unit will

occasionally sputter, particularly at start-up.

2. If the diverter supplied with the unit will

not attach directly to your faucet, install the

adapter. When done, or if the adapter is not

needed, connect the Sterilight unit diverter

valve assembly to the faucet (Figure 10).

3. Plug the power supply into an

available outlet.

The outlet MUST always have power

available. Do not plug the unit into an outlet

that can be switched on or off.

The unit is now ready for operation.

Figure 10

Attaching diverter

to Faucet

Figure 11

Turn on the faucet by pulling

the diverter valve flow

control knob outward.

The unit will automatically

come on.