For the filter to be removed, the filter

element must be saturated with water and all

internal seals must be wet. DO NOT ATTEMPT

TO REMOVE A FILTER ELEMENT THAT IS NOT

WET. Doing so may result in breakage of

the glass sleeve or lamp, and could result in

personal injury.

1. Disconnect unit from power source.

2. Run water through the unit to insure that the

filter is saturated and all seals are wet.

3. Remove the unit from its wall mount

(if wall mounted)

4. Grasp the unit firmly and unscrew the cap by

turning counterclockwise (Figure 13).

5. Once the cap is completely unscrewed, use

the tubing disconnect tool to disconnect the

outlet tube (Figure 14).

6. With the outlet tube disconnected, lift the

cap and filter out of the unit. It is not unusual

for the O-ring at the bottom of the filter to

stay on the glass sleeve (Figure 15).

7. Reach in and remove the lower filter O-ring

seal as shown (Figure 16).

8. Sanitize the unit prior to installing the

new filter. To do this, reinstall the cap

(without the filter installed), reconnect the

diverter outlet tubing and replace the

unit on its mount or stand. Reconnect

power and run water through the unit

for approximately 5 minutes. Without a

filter cartridge in the unit, some ozone

remains in the outlet water, sanitizing

the upper portion of the unit and the

outlet lines.

DO NOT DRINK water that has been run

through the unit without a filter.

9. Disconnect power and remove the cap as in

steps 3, 4 and 5 above.

10. To insure that the lower filter seal will slide

easily into the unit, wet the glass sleeve

(Figure 17).

11. The upper (large) seal fits into the top

Figure 15—Unscrewing cap

and removing filter

Figure 16

Removing lower O-ring

Lower O-ring

Figure 13

Disconnecting outlet tube

Figure 14

Disconnecting outlet tube