Sterilite Point-of-Use Drinking Water System User Manual

Page 9

Advertising
background image

9

glass sleeve in the unit. Ensure that the glass sleeve is wet,

and guide the filter over the sleeve (Figure 20).

Be sure to guide the outlet tube into the bottom fitting.

14. Tighten the cap and reconnect all fittings. Reconnect power.

15. Run water through the unit for 5 minutes to flush the filter

before use.

IMPORTANT! Use only filters supplied by your Sterilight dealer.

Approved filters are specifically matched to your unit. Using the wrong

filter will negatively effect unit operation, will void the unit warranty,

and can adversely affect the safety of water leaving the unit.

REPLACING THE UV LAMP

The Sterilight unit uses a high-intensity ozone generating lamp which

can be obtained from your Sterilight dealer. For proper unit operation,

use only lamps supplied by your Sterilight dealer. The lamp should be

replaced whenever it fails to light during operation.

cap. Push it firmly

into the

cap until it is

completely seated

(Figure 18). The

filter should stay

firmly in the to cap.

12. Ensure that the

lower filter O-ring

seal is in place

(Figure 19).

13. The lower seal

slides over the

Figure 17

Wet glass sleeve

Figure 18

Installing the filter into the cap

Figure 19

Checking lower O-ring seal

Figure 20

Installing the filter in the unit