General settings pages of the sub lcd menu, General settings page (1) – Sony DSR-70 User Manual

Page 73

Advertising
background image

Chapter 4

Time Data and Sub LCD Menu

Chapter 4

Time Data and Sub LCD Menu

73

General Settings Pages of the Sub LCD Menu

There are general settings pages (1) and (2).

General settings page (1)

1 PRESET/REGEN (regenerate) setting
Selects the value set in the internal timecode generator.

PRESET: Preset the initial value of the timecode

generated by the internal timecode generator,
either by a control panel operation or by remote
control from the device connected to the
REMOTE connector.

REGEN: Synchronize the internal timecode

generator with the timecode read by the internal
timecode reader.

2 F-RUN/R-RUN (free-run/rec-run) setting
Selects the progression method for the timecode
generated by the internal timecode generator.

F-RUN: Timecode progresses continuously from the

time when this unit is powered on, regardless of
the unit's operating status.

R-RUN: Timecode progresses only during recording.

3 DF/NDF (drop-frame/non-drop-frame) setting
(for DSR-70 only)
Selects DF to advance timecode in drop-frame mode,
and NDF to advance timecode in non-drop-frame
mode.

4 KEY INH (key inhibit) setting
Set to ON to disable the buttons on the control panel.
(Sub LCD menu operations can still be performed
even when this item is set to ON.)
You can select the buttons that are disabled under
setup menu item 118.
If you try to operate the disabled buttons, the message
“!!KEY INH.!” appears in the time data display area
on the sub LCD.

5 PB/EE (monitor signal) setting
Selects the video/audio signal output when the tape is
being fast forwarded or rewound, or when the unit is
stopped or on standy .

PB: Playback signal
PB/EE: Input signal in E-E mode

6 REMOTE setting
When the REMOTE/LOCAL switch is set to
REMOTE, selects the source for control of this unit.

9P: The unit is controlled from the device connected

to the REMOTE connector (D-sub9-pin).

i.LINK: The unit is controlled from the device

connected to the DV IN/OUT connector (DSBK-
140).

To switch to general settings page (2)

Press the PAGE button.

3

DF/NDF (drop-frame/non-drop-frame) setting
(for DSR-70 only)

TC GENERATOR

PRESET

KEY INH

OFF

F-RUN

EE/PB

PB

DF

REMOTE

9P

1

PRESET/REGEN (regenerate) setting

2

F-RUN/R-RUN (free-run/rec-run) setting

5

PB/EE (monitor signal) setting

4

KEY INH (key inhibit) setting

6

REMOTE setting

Advertising
This manual is related to the following products: