Suburban Mfg OXYGEN THERAPY DOOR 12155-00-DRDRAA User Manual

Page 25

Advertising
background image

Form No. 702703 Rev. E August, 2006

21

Owner’s Manual - Oxygen Therapy Door

Tools Required
„

5/8 in. open-end wrench

„

Utility knife

Procedure
The hose barb fitting connects the oxygen supply hose to the
nebulizer (Figure 21). To replace the fitting:

1.

Pull or cut the oxygen supply hose off the fitting.

2.

Hold the white, 4-arm knob on top of the regulator, and
unscrew the barb fitting with a 5/8 in. open-end
wrench.

Nebulizer Hose Barb

Fitting

P/N 854546

3.

To install the new fitting, hold the knob and tighten the
new fitting with the wrench.

4.

Push the oxygen supply hose onto the new fitting.
Note: A small amount of grease on the barbs will ease
assembly.

Figure 21. Nebulizer Barb Fitting

Barb Fitting

5/8 in. Hex

4-arm Knob

Oxygen

Supply Hose

Advertising