Temperature Estimating and Measuring Methods

The following methods can be used to estimate air cooling requirements and calculate junction temperature
based on thermo-couple temperature measurements.

Airflow Cooling Measurement Method

The relationship between air temperature and junction temperature is described in the following thermal
equation:

Tj = Ta + [Pd (

θ

jc +

θ

cs +

θ

sa)]

Note: Testing is done with the worst-case power draw, software loading, and ambient air temperature.

Determination of the ambient air temperature (Ta) and the “free-stream” air velocity is required in order to
apply the airflow method. The table "Heatsink-to-Air Thermal Resistance," illustrates the thermal resistance
between the heatsink and air (

θ

sa).

Note that the airflow velocity can be measured using a velocity meter. Alternatively it may be determined by
knowing the performance of the fan that is supplying the airflow. Calculating the airflow velocity is difficult.
It is subject to the interpretation of the term “free-stream.”

Note: The Airflow Cooling Estimate method is an estimate. Use it solely when an approximate value

suffices. Accuracy can only be assured using the Case Temperature measuring method or the
Heatsink Temperature measuring method. Apply these methods to insure a reliable performance.

"Heatsink-to-Air Thermal Resistance," specifies the thermal resistance of the heatsink as a function of the air
velocity.

Air Velocity Specifications

These specifications are recommended for a typical configuration:

Airflow Topside

150 LFM @ 30

°

C up to 2,000 feet, altitude, maximum

300 LFM @ 40

°

C up to 10,000 feet, altitude, maximum

Airflow Bottomside

100 LFM @ 30

°

C up to 2,000 feet, altitude, maximum

150 LFM @ 40

°

C up to 10,000 feet, altitude, maximum

Heatsink-to-Air Thermal Resistance

Air Velocity

(ft/min)

[1]

1. Ducted airflow through the heatsinks.

150

200

300

400

500

650

800

1000

θ

SA

(

°

C/W)

[2]

2. Airflow direction parallel to the shorter axis of the pin-fin heatsink (1.9"L x 3.6"W x 1.1"H)

1.21

1.05

0.91

0.84

0.78

0.72

0.67

0.64