19

400 MHz CPU, 4.0 MB E-Cache

UltraSPARC

-II CPU Module

SME5224AUPA-400

Advanced Version

July 1999

Sun Microsystems, Inc

Thermal Definitions and Specifications

Term

Definition

Specification

Comments

Tj

Maximum device
junction
temperature

85

°

C,

The Tj can't be measured directly by a thermo-couple
probe. It must always be estimated as Tj or less. Less is
preferred.

Tc

Maximum case
temperature

76.7

°

C

Measurable at the top-center of the device. Requires a hole
in the base of the heatsink to allow the thermocouple to be
in contact with the case. Maximum case temperature is
specified using a CPU device at its maximum power
dissipation.

Ts

Heatsink
temperature

75

°

C

Measurable at the temperature of the base of the heatsink.
The best approach is to embed a thermocouple in a cavity
drilled in the heatsink base. An alternative approach is to
place the thermocouple between the fins/pins of the heat-
sink (insulated from the airflow) and in contact with the
base plate of the heatsink.

Ta

Module ambient air
temperature

see page 20

The air temperature as it approaches the heatsink.

Pd

Typical power
dissipation of the
CPU

19.0 W

The worst case compute loads over the entire process
range.

θ

jc

Maximum
junction-to-case
thermal resistance
of the package

0.5

°

C/W

The specification for the UltraSPARC™–II, 400 MHz CPU
in a ceramic LGA package.

θ

cs

Case-to-heatsink
thermal resistance

0.1

°

C/W

Accuracy of this value requires that good thermal contact is
made between the package and the heatsink.

θ

sa

Heatsink-to-air
thermal resistance

see page 20

This value is dependent on the heatsink design, the airflow
direction, and the airflow velocity.

Va

Air velocity

see page 20

The ducted airflow.

Advertising