Readback checksum

error

-12

A checksum, generated from reading back data that was written to

the destination device, was incorrect. An error during transmission

or a write error to the destination device could cause this.

There is no more heap

space available

-14

There is no more heap space available for the download

procedure. Restart IPL and retry the download. If the failure

persists, contact service with details of what is being downloaded.

Insufficient data

available to complete

record

-21

A Symbol HEX file download was attempted but the HEX file is

invalid. Ensure the file is in Symbol HEX file format.

Invalid Symbol HEX file

-23

A Symbol HEX file download was attempted but the HEX file is

invalid. Ensure the file is in Symbol HEX file format.

Unrecognized or

unsupported HEX record

-24

The Symbol HEX file being downloaded contains an invalid or

unrecognized HEX record. Ensure the file is in proper Symbol HEX

file format.

Invalid data in HEX file

-25

The Symbol HEX file being downloaded contains invalid data.

Ensure the file is in proper Symbol HEX file format with valid HEX

data.

Exceeded max size

-26

The download file is too large to fit into the space allocated for it.

Either make the file smaller or increase the space allocated for it by

altering the partition table.

Partition is not valid on

this device

-27

The downloaded file specifies a partition entry that does not exist

on the device. Only download files that are valid for this device, or

change the partition table so that the new file is valid on the device.

Wrong destination code

-28

A specific partition was chosen from the Main Menu (not Auto

Select) but the file selected for download was for another partition.

Ensure that the partition selected from the Main Menu matches the

file selected for download.

File type does not

support IPL Auto Select

-29

Monitor, Power Micro and Partition Table cannot be loaded with

Auto Select. Select the appropriate area, and try again.

Non-contiguous record

found

-30

A Symbol HEX file download was attempted but the HEX file is

invalid. Ensure the file is in Symbol HEX file format.

Timed Out - No data

-31

IPL was waiting for data from the source device but timed out

before receiving any. Check the source device connectivity and

retry.

Fail: Buffer Overrun

-32

The serial port device could not keep up with incoming data. Retry

the serial download with a lower baud rate.

Table 7-4