3-2 Reference Sync Signals

Chapt

er

3

Pre

par

at

ion
s

3-2 Reference Sync
Signals

This section describes how reference signals for the video
output signals and servo system are selected.
The output from the internal reference video signal
generator is supplied to the output video signal and servo
circuits as a reference signal.

3-2-1 Selecting Reference Sync
Signal Depending on Operational
Status

The reference sync signal selection switches automatically
between REF and INPUT depending on the menu settings
and the operating status of the unit, as shown in the
following table.

a) EE: In E-E mode

PB: Playing back (normal playback, jog mode, shuttle mode, variable

speed mode and stop mode)

EDIT: Edit preset enabled
REC: Recording

• When there is no HDSDI signal input whereas INPUT is

selected, the unit synchronizes with the REF signal.

• When there is no REF signal input whereas REF is

selected, no external reference signal is used. In this
case, the unit synchronizes with the internally generated
reference signal.

3-2-2 Connecting Reference Signals

Connect reference signals as shown below, according to
the way in which the unit is to be used.

• Connections for recording from a switcher or

signal generator

P03:VID
PROC
F2(REF VID)
setting

Menu
item
309
setting

Menu
item 334
setting

Unit’s
operational
status

a)

Reference
signal
setting

EXT

NORMAL EE

REF

PB

EDIT

REC

INPUT

EE

INPUT

PB

REF

EDIT

REC

REF

AUTO1

NORMAL EE

PB

EDIT

REC

INPUT

INPUT

EE

PB

REF

EDIT

REC

INPUT

INPUT

EE

PB

EDIT

REC

REF

AUTO2

NORMAL EE

REF

PB

EDIT

INPUT

REC

INPUT

EE

PB

REF

EDIT

INPUT

REC

INPUT

EE

PB

EDIT

REC

Notes

P03:VID
PROC
F2(REF VID)
setting

Menu
item
309
setting

Menu
item 334
setting

Unit’s
operational
status

a)

Reference
signal
setting

HDSDI
INPUT

REF. VIDEO
INPUT

75

Ω termination

switch: ON

Reference signal

Switcher or signal generator

HDW-1800/D1800