9-4 Items in the Extended Setup Menu

Chapt

er 9 Set

u

p

Men

u

s

607

U-BIT BINARY
GROUP FLAG

Specify how to use the user bits in the timecode generated by the timecode generator.
000: Character set not specified
001: 8-bit characters compliant with ISO 646 and ISO 2022
010: Undefined
011: Undefined
100: Undefined
101: SMPTE 262M Page/line multiplex system
110: Undefined
111: Undefined

608

PHASE
CORRECTION

Select whether to carry out phase correction control on the LTC generated by the
timecode generator.
OFF: No control
ON: Carry out control.

609

TCG CF FLAG

Select whether the color framing flag is set in the blank bit of the timecode data.
OFF: Not set.
ON: Set.
AUTO: Control the color framing flag setting as follows according to the operation mode

of the timecode generator (TCG).
- When the TCG is in INT-PSET mode: Set the color framing flag in the blank bit of

generated timecode data.

- When the TCG is in INT-LTC or INT-VITC mode and the number of fields for

capstan lock is 4F or 8F: Set the color framing flag in the blank bit of generated
timecode data.

- When the TCG is in other than the above modes: Do not set the color framing flag

in the blank bit of generated timecode data.

For more information about the TCG operation mode, see TCG mode (page 18). For
details on settings of the TCG, see the description of function menu page P02: TC
(page 65). Fo
r details on settings of the number of fields for capstan lock, see the
description of function menu page P04: MISC-1 (page 67
).

610

REGEN CONTROL
MODE

Select whether timecode is automatically regenerated.
AS&IN: In automatic editing in assemble mode or insert mode with this unit as a recorder

(AUTO EDIT), regardless of the settings of F1 (TCG SRC) and F2 (TCG MODE) in
function menu page P02: TC, the timecode generator regenerates according to the
timecode on the tape.

ASSEM: In automatic editing (AUTO EDIT) in assemble mode with this unit as a

recorder, regardless of the settings of F1 (TCG SRC) and F2 (TCG MODE) in
function menu page P02: TC, the timecode generator regenerates according to the
timecode on the tape.

MANU: Regardless of whether this unit is the recorder or player, the timecode generator

operates in accordance with the settings of F1 (TCG SRC) and F2 (TCG MODE) in
function menu page P02: TC.

FULL: Whether in local or remote operation and regardless of the settings of F1 (TCG

SRC) and F2 (TCG MODE) in function menu P02: TC, when any of F2 (INS TC), F3
(INS CUE), and F5 (ASSEMBLE) to F10 (INS A4) in function menu page P07:
E.PRESET is lit, the timecode generator regenerates according to the timecode
played back from the tape.

617

LTC OUTPUT
PHASE

Set the output phase of timecode signals (LTC).
TCG/R: Output the playback timecode signal during playback.

When the edit preset function is on, and when recording, output the timecode signal
generated by the internal timecode generator.

INPUT: Use the same phase as the input video.
OUTPT: Use the same phase as the output video.
AUTO: Use the same phase as the input video when editing, and otherwise, use the

same phase as the output video (when playback, recording, etc.)

Menu items in the range 600 to 650, relating to the timecode generator (Continued)