9-4 Items in the Extended Setup Menu

Chapt

er 9 Set

u

p

Men

u

s

743

P

R

LEVEL (HD)

Adjust the P

R

level of the high-definition video signal output from the HDSDI

OUTPUT connector.

0.0% (0H) to 100% (800H) to 141.3% (B4EH)

745

SETUP LEVEL (HD)

Adjust the setup level of the high-definition video signal output from the HDSDI
OUTPUT connector.

0 to 110H to 220H

746

SYNC PHASE (HD)

Control the H sync phase of the high-definition video signal output from the HDSDI

OUTPUT connector according to the menu.

0 to 80H to FFH

747

SYNC PHASE FINE (HD)

Fine control the H sync phase of the high-definition video signal output from the

HDSDI OUTPUT connector according to the menu.

0 to 3FFH

Menu items in the range 800 to 899, relating to audio control

Item number

Item name

Settings

801

DIGITAL JOG SOUND

Turns the digital jog sound on and off.
OFF: Digital jog sound is turned off.
Audio of digital channels not subjected to speed correction is output. When the
tape stops, after one second the audio is muted.
ON: Digital jog sound is turned on.
When the tape speed is in the range x–1 to x+1, speed correction is carried out,
and the same jog sound as a conventional analog VTR is output.

802

DIGITAL AUD MUTING IN
SHUTTLE MODE

Set the digital audio muting conditions during shuttle playback.
OFF: Not muted.
CUEUP: Muted during cueup or preroll operations.
FULL: Muted in shuttle mode.

803

DIGITAL AUDIO FADE
TIME

Specify the time for cross-fade or fade in/out editing of digital audio signals.

5ms, 10ms, 15ms, 20ms, 25ms

a)

, 50ms

b)

, 85ms, 115ms

c)

Note

The cross-fade or fade in/out operation means that the recording is rewritten from
the OUT point for the length specified by this setting. Even at the minimum 5ms
setting, a length of recording corresponding to a field is rewritten.
To avoid rewriting, set menu item 317 “AUDIO EDIT MODE” to “CUT”. In this case
there is an audio discontinuity at the edit point. There is no effect on the recorded
video signal.

805

AUDIO MONITOR
OUTPUT MIXING

Select the audio mixing method used for digital audio signals supplied to the
MONITOR OUTPUT connector.
ADD: Simple addition
RMS: Root-mean-square
AVE: Simple average

806

LEVEL METER SCALE

Select the digital audio level display mode.
PEAK0: Display the audio level as negative values with the maximum level set to

“0 dB”.

REF.0: Display the audio level as positive and negative values with the reference

level set to “0 dB”.

807

AUDIO OUTPUT PHASE

Select the output timing of digital audio playback signals (HDSDI, SDI and AES/

EBU only). The reference position is 80H; when the setting is less than 80H, the
output timing is advanced, and when it is higher than 80H, the output timing is
delayed. (at 80H, 128 samples = approx. 2.7 ms, and 1 sample = approx. 20 µs)
0 to 80 to FF: Set in this range.