3.6.4. POP3 (Email Reception) Settings

3.6.4.1. Basic Settings

Variable Name

Setting Range

Initial Value (Default Settings)

POP Protocol

ENABLE/DISABLE

DISABLE

Check Interval (min.)

3-60

15

Local Time Zone

“-12:00” to”+12:00”

“+08:00”

User Profile

ENABLE/DISABLE

DISABLE

3.6.4.2. Account Settings For Each User (User Profile 1 to 4)

Variable Name

Setting Range

Initial Value (Default Settings)

POP Server Name

Host name or IP address

None

POP User Name

Max. 31 char. of ASCII

None

POP Password

Max. 31 char. of ASCII

None

POP Port Number

1-32767

110

User APOP

YES/NO

NO

Delete Mail after Retrieve

YES/NO

NO

Maximum Retrieve (Kbyte)

0-32767

64

Filter settings

Max. 78 char. of ASCII (Japanese lang. OK) (*1)

None

Use the following sentence by connecting using “&” (AND conditions) or “|” (OR
conditions) for the (*1) filter settings.

Class

Target for
Inspection

Example of Use

S:

Subject

S:news & S:daily

Prints mail whose subject is daily and news.

F:

From

F:rt-users

Prints mail from rt-users.

T:

To

T:[email protected]

Prints mail to support.

C:

CC

C:user | T:user

Prints mail that includes addressee or user in CC field.

3.6.5. SMTP (Email Sending) Settings

3.6.5.1. Basic Settings

Variable Name

Setting Range

Initial Value (Default Settings)

SMTP Protocol

ENABLE/DISABLE

DISABLE

SMTP Server Name

Max. 78 char. of ASCII

None

From Address

Max. 78 char. of ASCII

None

To Address

Max. 78 char. of ASCII

None

Check Interval(min.)

1-10000

10

SMTP Port Number

1-32767

25

Signature Line1

Max. 63 char. of ASCII

-------------------

Signature Line2

Max. 63 char. of ASCII

Star Micronics IFBD-HE03/04

Signature Line3

Max. 63 char. of ASCII

[(Ethernet Address)]

Signature Line4

Max. 63 char. of ASCII

-------------------

3.6.5.2. Event to Address Settings

Variable Name

Setting Range

Initial Value (Default Settings)

Offline ON/OFF

OFF

Paper Empty

ON/OFF

OFF

Fault ON/OFF

OFF

NearEnd ON/OFF

OFF