Shenzhen High Power Tech H7920 User Manual

Page 26

Advertising
background image

Galaxy H7920 Mobile Router User Manual

Chapter 3: Router Configuration

M80-792001-01

41

Data Service Center (DSC)

DSC can be enabled or disabled. Default setting is "Enable".

Type of Service

There are two options:

Client: The Galaxy router will act a client function to send data to the

specified DSC.

Server: The Galaxy router will act a server to listen the data transfer

from the specified DSC.

Protocol

There are TCP and UDP options for selection. Based on past experience,

GPRS/EDGE or CDMA 1x channel is not reliable due to radio propagation. UDP is

recommended for transmitting real time information with data checksum, such
as SCADA system. TCP protocol may be better for transmitting files.

DSC IP Address or Domain

Data Service Center (DSC) IP Address or Domain is the server address that

receives data from serial port device connecting with Galaxy router. It supports

IP address or domain name.

DSC Port


Defining Data Service Center communication port, it can be changed with the

system planning. The default port is 5002.

Heartbeat Interval

Galaxy H7920 Mobile Router User Manual

Chapter 3: Router Configuration

M80-792001-01

42

For many applications, it requires to keep the links always online. The heartbeat

setting should be set to keep the links alive. However, the heartbeat is the data

traffic packets and it may be charged (depends service provider). You have to set

a right heartbeat interval in accordance with application. Normally, we suggest

the 50 seconds heartbeat interval for most of applications.

Router ID

It is the router unique identity name at data service center. By the unique ID, you

can transmit/receive data to/from remote site and also manage remote router.

Set it according to the application system planning.

Serial Port Setting

Galaxy router can be used to connect non-IP based data terminal such as POS,

RTU and PC Hypertext Terminal. The serial port should be configured properly

before putting it in service.

Click "Start"->"Special Setting"->"Serial Port Setting" menu to start this setup

page.

Serial Port

There are "Enable" and "Disable" switches.


Default setting: Disable.

If the serial port is enabled, the DSC IP address or domain name must be

specified.

Interface

Select serial port interface type: RS-232 or RS-485; RS-485 is not available at this

version hardware.

Advertising