5 ac input requirements, 1 ac inlet connector, 2 redundant ac inlets – SSI America ERP2U User Manual

Page 11: 3 ac input voltage specification, Ac input requirements, Ac inlet connector, Redundant ac inlets, Ac input voltage specification, Table 2: thermal requirements

Advertising
background image

SSI

ERP2U Power Supply Design Guide, V2.31

- 11 -

The power supply shall operate within all specified limits over the T

op

temperature range. All airflow shall pass

through the power supply and not over the exterior surfaces of the power supply.

Table 2: Thermal Requirements

ITEM DESCRIPTION

MIN

MAX

UNITS

T

op

Operating temperature range.

0

50

°C

T

non-op

Non-operating temperature range.

-40

70

°C

The power supply must meet UL enclosure requirements for temperature rise limits. All sides of the power supply
with exception of the air exhaust side, must be classified as “Handle, knobs, grips, etc. held for short periods of
time only”.

5

AC Input Requirements

STATUS

Required

The power supply modules shall incorporate universal power input with active power factor correction, which shall
reduce line harmonics in accordance with the EN61000-3-2 and JEIDA MITI standards.

5.1 AC Inlet Connector

STATUS

Required

The AC input connector shall be an IEC 320 C-14 power inlet. This inlet is rated for 15 A/250 VAC. This
connector may be located on the module or on the cage.

5.2 Redundant AC Inlets

STATUS

Recommended

The power supply assembly may have dual redundant AC inlets. The power supply shall be able to operate over
its full, specified range of requirements with either or both AC input powered. If there is a loss of one AC inlet the
power supplies shall continue to operate with no interruption of performance. It is required that all redundant
power supply modules be present to support redundant AC inlets.

5.3 AC Input Voltage Specification

STATUS

Required

The power supply must operate within all specified limits over the following input voltage range. Harmonic
distortion of up to 10% THD must not cause the power supply to go out of specified limits. The power supply shall
operate properly at 85 VAC input voltage to guarantee proper design margins.

Advertising