10 ac line fast transient specification, Ac line fast transient specification, Table 7: ac line surge transient performance – SSI America ERP2U User Manual

Page 14

Advertising
background image

SSI

ERP2U Power Supply Design Guide, V2.31

- 14 -

recoverable

Table 6: AC Line Surge Transient Performance

AC Line Surge

Duration

Surge

Operating AC Voltage

Line Frequency

Performance Criteria

Continuous

10%

Nominal AC Voltages

50/60 Hz

No loss of function or performance

0 to ½ AC
cycle

30%

Mid-point of nominal AC
Voltages

50/60 Hz

No loss of function or performance

5.10 AC Line Fast Transient Specification

STATUS

Recommended

The power supply shall meet the EN61000-4-5 directive and any additional requirements in IEC1000-4-5:1995
and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions:

• These input transients must not cause any out-of-regulation conditions, such as overshoot and

undershoot, nor must it cause any nuisance trips of any of the power supply protection circuits.

• The surge-withstand test must not produce damage to the power supply.
• The supply must meet surge-withstand test conditions under maximum and minimum DC-output load

conditions.