8 ripple / noise, Ripple / noise, Table 23: capacitve loading conditions – SSI America ERP2U User Manual

Page 23: Table 24: ripple and noise

Advertising
background image

SSI

ERP2U Power Supply Design Guide, V2.31

- 23 -

Required

The power supply shall be stable and meet all requirements, except dynamic loading requirements, with the
following capacitive loading ranges.

Note: Up to 10,000

μF of the +12V capacitive loading may be on the +12V1 output.

Table 22: Capacitve Loading Conditions

Output MIN

MAX

Units

+3.3 V

10

12,000

μF

+5 V

10

12,000

μF

+12 V

10

11,000

μF

-12 V

1

350

μF

+5 VSB

1

350

μF

6.8 Ripple / Noise

STATUS

Required

The maximum allowed ripple/noise output of the power supply is defined in Table 24. This is measured over a
bandwidth of 0 Hz to 20 MHz at the power supply output connectors. A 10

μF tantalum capacitor in parallel with a

0.1

μF ceramic capacitor are placed at the point of measurement.

Table 23: Ripple and Noise

+3.3 V

+5 V

+12 V

-12 V

+5 VSB

50 mVp-p

50 mVp-p

120 mVp-p

120 mVp-p

50 mVp-p