8 control and indicator functions, 1 pson, Control and indicator functions – SSI America ERP2U User Manual

Page 30: Pson, Figure 5: pson# signal characteristics, Table 30: pson, Signal characteristic

Advertising
background image

SSI

ERP2U Power Supply Design Guide, V2.31

- 30 -

8

Control and Indicator Functions

The following sections define the input and output signals from the power supply.

Signals that can be defined as low true use the following convention:

signal

#

= low true

8.1 PSON#

STATUS

Required

The PSON

#

signal is required to remotely turn on/off the power supply. PSON

#

is an active low signal that turns

on the +3.3 V, +5 V, +12 V, and -12 V power rails. When this signal is not pulled low by the system, or left open,
the outputs (except the +5 VSB and Vbias) turn off. This signal is pulled to a standby voltage by a pull-up resistor
internal to the power supply. Refer to Figure 4 for timing diagram.

Table 29: PSON

#

Signal Characteristic

Signal Type

Accepts an open collector/drain input from the system.
Pull-up to VSB located in power supply.

PSON

#

= Low

ON

PSON

#

= Open or High

OFF

MIN

MAX

Logic level low (power supply ON)

0 V

1.0 V

Logic level high (power supply OFF)

2.0 V

5.25 V

Source current, Vpson = low

4

mA

Power up delay: T

pson_on_delay

5 ms

400 ms

PWOK delay: T

pson_pwok

50

ms

5.25V

≤ 1.0 V

PS is

enabled

≥ 2.0 V

PS is

disabled

1.0V

2.0V

Enabled

Disabled

Hysteresis

≥ 0.3V and/or other de-bounce method

0V

Figure 5: PSON# Signal Characteristics

Advertising