Output connection – Samsung SSA-S2000 User Manual

Page 13

Advertising
background image

English _ 13

INSTALLATION AND EXTERNAL CONNECTION

Output Connection

Connect the 10-pin and 7-pin connectors of the controller as follows:

- Door open (POWER FAIL SAFE) when the power is disconnected from the door lock (Door Relay)

Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
Connect the relay NC line (blue with white stripes for locking the door) to the plus(+) line of the door lock.
Connect the minus (-) line of the door lock to GND (-).

- Door close (POWER FAIL SECURE) when the power is disconnected from the door lock (Door Relay)

Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
Connect the relay NO line (white with red stripes for locking the door) to the plus (+) line of the door lock.
Connect the minus (-) line of the door lock to GND (-).

- Alarm Connection (Alarm Relay)

Connect the relay COM (white for the alarm device) to DC +12V.
Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm device.
Connect the minus (-) line of the alarm device to GND (-).

- Chime Bell Connection (the chime bell operated by TTL-level signal must be installed in advance.)

Connect the chime bell line (brown with white stripes) of the controller to DC +5V.
Connect the GND line of the power supply unit to GND (-) of the chime bell.

Press

ESC

to a0ctivate EthNeT chime bell.

1.
2.
3.

1.
2.
3.

1.
2.
3.

1.
2.

3.

X

Y

Z

[

\

]

^

_

`

lzj

lu{

W

iŒ““

zzhTzYWWW

Advertising
This manual is related to the following products: